云数据中心

云数据中心

硅片、CPU和GPU散热

刀片和存储保护

机架和机箱

为制造而设计

资源

云数据中心
硅片、CPU和GPU散热

硅片、CPU和GPU散热

硅, cpu, 和gpu是成功的企业和云计算安装的基础. 应用各种技术的高性能热管理,最大限度地提高处理能力.

液体冷板

3 dvcs

热虹吸管

硅片、CPU和GPU散热
刀片和存储保护

刀片和存储保护

使用beat365官方网站大全保护刀片和数据存储免受数据中心环境的影响. Leverage dampeners minimize mechanical and acoustic vibration to improve read-write accuracy and data integrity. 密封和屏蔽防止进入, 电磁干扰, 和火花电压,以最大限度地提高系统的正常运行时间.

空气管理

噪音beat365官方网站大全

EMI材料

刀片和存储保护
机架和机箱

机架和机箱

服务器机架和机架机箱是企业和云计算安装的框架. Racks can be optimized for air or liquid cooling systems with advanced blower trays or integrated liquid cooling and high-performance 冷却剂分配装置(cdu). 配有仪表和智能软件, systems can quickly respond to varying processor loads and optimize cooling and power usage for on-demand cooling.

冷却分配单元(cdu)

信息和标签

电气绝缘材料

机架和机箱
为制造而设计

为制造而设计

Leverage Boyd’s global engineering team and their enterprise experience to design computing solutions that help you gain a competitive advantage.

制造能力

工程设计

为制造而设计

云数据中心

云 data center installations are growing fast with accelerated adoption of artificial intelligence and the Internet of Things (IoT) integrating smart functionality and connectivity across most industries. 对便利的偏好, 灵活性, 速度, mobility and responsiveness is driving device performance and functionality that creates vast amounts of data to transmit and store. 云计算存储、处理、网络和分析所有这些数据和数字功能. 消费趋势和创新使得云计算越来越成为企业运营的内在要素, 消费者掌控着他们的生活. 云为现代社会提供动力.

降低数据中心所有权的总成本

集成beat365官方网站大全最大限度地减少或消除浪费, 维护成本和停机时间降低了数据中心所有权的总体总成本.

快速迭代设计,加快上市速度

Customer-first service with market leading 速度 and responsiveness combined with decades of thermal design expertise and robust, 专有的建模工具使Boyd能够快速迭代设计并加快上市速度.

雪中的铜热管

企业beat365官方网站大全

点击上面的图片打开3D渲染页面.

如何使用机架内液冷系统冷却数据中心?

(查看成绩单)

机架内液体冷却

集成在服务器机架内的液冷系统旨在 管理机箱内的热量 通过一系列热源或服务器. 紧凑的, 低调, 高性能, 热致密液体系统在现有的底盘设计中开辟了额外的空间, 在相同的空间中为更多的计算和功率密度提供空间. 在摇滚 冷却剂分配装置 (cdu)或液体冷却回路可以连接到现有的设施水冷却系统, 积分冷却 将刀片或切屑水平用液冷板冷却 为热源和液体系统之间的最大界面提供定制的天际线. 快速断开与旋转接头,使服务易于访问和快速.

在相同的内存占用中增加计算密度

Low profile liquid cooling systems offer higher performance in a smaller footprint and create additional design space with optimized thermal density.

响应式全局定位

随着地缘政治的变化,客户的区域需求不断变化,博伊德与客户一起行动, 区域采购策略的转变, 近岸或全球制造业转移.

底盘液冷

液体冷却系统 集成在一系列机箱中,旨在管理跨多个服务器机架的更高热负荷. 线性 冷却剂分配装置(cdu) can be fully self-contained or connect into installed facility liquid systems with intelligent instrumentation that optimizes energy use, 感觉流, 压力, temperature and leak detection for variable peak performance and preventive protection meaning cloud systems get the exact, 最优, 系统在需要时需要随需应变的冷却性能.

极端空气冷却

那些希望突破空气冷却的界限并推迟向液体冷却过渡的人依赖于博伊德的研究 极致风冷系统创新. Extreme air cooling systems help hyperscale compute designers maximize compute density by leveraging highly efficient two-phase cooling technologies that rapidly absorb and transport heat away from heat sources to remote regions within the server or chassis to access more design space for larger heat sinks and better access to air flow. 高压 风机和鼓风机 enable denser systems and heat sink fins for more extreme cooling with the added benefit of operating with less noise and tonal vibration than traditional fans, 从而提高硬盘性能和更安静, 更安全的数据中心.

扩展风冷创新,安全过渡到液体

Boyd的重叠技术组合使液体成为可能, 浸, 两相, and air cooling innovation to co-exist; recommending and blending the right technologies for each custom application, extending the performance boundaries of traditional air cooling systems and assuring a safe migration to liquid cooling systems when appropriate.

提高效率和可靠性

Boyd的云beat365官方网站大全很酷, seal and protect some of the most demanding data centers in the world with solutions that help customers increase performance efficiency, 优化资源利用, 能量回收最大化, 并提高所有系统级别的可靠性.

最大限度提高空气冷却效率

Improve data center energy efficiency and thermal system performance by optimizing cooled air use and hot air exhaust in air cooled systems. FR V-0 气阻器由 SOLIMIDE® polyimide foam block air and insulate noise with unique differentiated characteristics like high temperature resistance, 耐燃性, 可降解, 极低的密度和重量. 漏气密封件和气隙填充物防止冷空气损失, 去除设计中储存冷空气或热空气的口袋, 并连接内部气流通道. Air baffle assemblies commonly feature flame rated FR V-0 electrically insulating materials that are thermoformed or folded into airflow management channels, 管道, 并管理分流, 改变服务器内部的气流,以最有效地将冷空气引导到散热器.

密封和屏蔽云数据中心

博伊德风管和气流管理beat365官方网站大全, 比如热成型挡板, 是否用于提高传统风冷系统的效率. Prevent device or assembly overheating or premature failure from lost or decreased airflow velocity that reduces heat sink efficiency with FR-V0 rated electrically-insulating air flow baffles. 博伊德提供了几个额外的空气阻塞, 空气屏蔽, 垫片, and air diverter material options optimized for sealing force and compression force deflection to optimize cool air use in an enclosure, 包括博伊德的出色表现 聚酰亚胺泡沫SOLIMIDE®,丁腈,三元乙丙橡胶,聚氨酯和硅胶泡沫. 外壳, 住房, and environmental seals are a critical need and constant challenge for enterprise systems to protect against dust and water ingress or other contaminants. Boyd foam and mesh air filters protect sensitive components from particle and dust build up that hinders performance and may cause failures. 这些密封泡沫和垫片防止空气泄漏和优化气流, 使冷却系统运行在最高性能.​

创建更安全的数据中心

Boyd的beat365官方网站大全考虑了完整的数据中心环境,提供了安静的beat365官方网站大全 减少环境噪音污染 更安全的数据中心操作.

数据中心热管理和工程beat365官方网站大全 (查看成绩单)

电力电子的两相增强型空气冷却

(查看成绩单)

数据中心噪声和振动缓解

除了环境污染物, 噪音及振动, 电, 复杂的内部电子元件会降低系统的可靠性和完整性, 增加维护费用和系统停机时间. 博伊德全面的保护beat365官方网站大全改善了数据中心, 网络和连接系统的性能和最大化的正常运行时间 减轻噪音和振动的传播, 提高电子信号完整性, improving electrical shock protection and fire safety by blocking 火花电压 inside an enclosure V-0 flame rated dielectric insulators.

UL标签和覆盖层绝缘

Enterprise computing systems incorporate a surplus of components and subsystems that require clear identification to preserve peak functionality and performance. 博伊德定制的警告标签, 管理图形, 复杂的图形叠加, 系统信息标签, 阻燃电缆管理beat365官方网站大全, and serialized identification labels aid in the organization of any size data center facility from world class hyperscale computing centers to smaller edge computing sites. 信息和电介质覆盖 设计和印刷在UL等级的电绝缘原材料上,有助于UL测试, 批准, 和可追溯性. 通过与Boyd一起制造和组装,提高硬件的可追溯性 符合UL 969标准的警告和法规标签. 增加输入/输出网线的组织, 电线, 和软管的液体冷却系统与博伊德的综合钩和环电缆管理系统.

集成硅和处理器冷却

硅, cpu, gpu不断突破最大处理器能力的极限, 受热可达性的限制. 更大的热密度使更高的处理能力,创造市场竞争优势. Boyd的重叠技术组合使液体成为可能, 浸, 两相, and air cooling innovation to co-exist; recommending and blending the right technologies for each custom application, extending the performance boundaries of traditional air cooling systems and assuring a safe migration to liquid cooling systems when appropriate.

热管理简介

全谱芯片冷却技术

密度高, 远程热管散热器组件,液体冷却循环,高度 定制液体冷板 with custom skylines create the most efficient thermal interface between air or liquid systems and the processors. 具有为所有主要硅品牌设计最佳热beat365官方网站大全的经验, Boyd’s greatest value to server and data center designers is our partnership to custom design processor cooling solutions specific to their unique installations of these standard chips. 我们的硅, CPU and GPU thermal solutions are not one-size-fits all but customized to maximize thermal efficiency for each unique system installation, 最大限度地发挥系统的全部功能,并创造性能差异.

数据存储阻尼器和服务器密封

Improve cloud data center system performance and reliability with greater read-write accuracy and 速度 as well as protection against data center operational environments. 博伊德的beat365官方网站大全 抑制振动,吸收冲击 从机械和声学来源,如系统操作, 声音, 传统的空气冷却系统有许多运动部件在高转速下运行. 我们是世界上最重要的管理企业噪音、振动和粗糙度的专家 硬盘驱动器阻尼. 服务器机箱也必须密封,防止水或灰尘进入。 电磁干扰, LED相声,以及 火花电压 用于操作峰值性能和系统正常运行时间.